Staging - Reverse Osmosis
Advanced Reverse Osmosis Technology
Staging - “Reject Staging” refers
to a technique where the reject from one group of RO
pressure vessels becomes the feed stream of a second group of RO
pressure vessels. Reject staging
is used to increase the recovery of water. A one stage system typically
could recover 50 - 60% of the feed water stream with 2 and 3 stage
systems operating at 75 - 80% and greater than 85% respectively.
“Product Staging” referred to as “multiple pass”,
is a technique where the product of the first group of RO
pressure vessels becomes the feed water stream for a second stage.
Product staging is used to increase the quality of the product water.
For further information or assistance please contact Reverse Osmosis
Chemicals International on +44 (0) 161 877 2334 or
e-mail info@rochemicals.com.
|